15) Move the control switch to the "OFF" position. 
16) Disconnect the float switch vent hose from the drain hose tee. Move the service switch 
to the "DRAIN" position and the control switch to the "SERVICE" position.
17) From the tee on the drain hose, blow the drain water valve out using compressed air or 
carbon dioxide. 
18) Move the service switch to the "CIRC" position and the control switch to the "OFF" 
position.
19) Reconnect the thermistor to the K3 connector on the control board. Reconnect the 
water pump connector.
0) Close the inlet water supply line drain valve.
1) Remove all ice from the dispenser unit/storage bin and clean the dispenser unit/storage 
bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
) Turn off the power supply. 
3) Replace all removed parts and panels in their correct positions.
Harvest Water Valve Hose
Harvest Water Valve 
Wash Valve 
Fill Water Valve 
Drain Water Valve 
Fill Water Valve Hose 
Float Switch Vent Hose
Suction Hose
Drain Hose Tee
Fig. 5