Basic Recorder without Display 
3.1 Overview 
Introduction 
Set up the functionality of the models that do not have a display and keypad using configuration and input 
switches. Each pen channel in the recorder has an associated printed circuit assembly (PCA) shown in 
Figure 3-1. The configuration switches are the SW1 switchbank. The input switches are the SW6 
switchbank. If your recorder is equipped with two pens, the printed circuit assemblies for the two pens can 
be set up differently. The PCA for pen 1 (purple) is on the right (when facing the recorder); the PCA for 
pen 2 (red) is on the left (if present).    
Set up is fast and easy. This section includes a table that shows the various available combinations of 
recording selections (such as chart range, length of time for single rotation of chart, whether the input is 
linear or non-linear), input actuation types, and whether jumper R56 should be in or out. Find your desired 
configuration for the pen 1 channel on the table, then set the SW1 and SW6 switches as indicated. Repeat 
the process for the pen 2 channel, if available on your recorder, and set up is complete. 
What’s in this section? 
The following is a list of topics covered in this section. 
Topic See 
Page 
3.1  Overview 
3.2  Configuration (Recording Set Up) 
3.3  Startup and Operation 
    
  WARNING—SHOCK HAZARD   !
 
SET THE SWITCHES DESCRIBED IN THIS SECTION WITH THE UNIT 
POWER DISCONNECTED. DO NOT TOUCH POWER CONNECTIONS  
AT TB1. FAILURE TO OBSERVE THIS PRECAUTION CAN RESULT IN 
EXPOSURE TO A POTENTIALLY LETHAL SHOCK HAZARD. MORE THAN 
ONE SWITCH MAY BE REQUIRED TO DE-ENERGIZE UNIT.