Honeywell NXL Benutzerhandbuch

Seite von 96
20(96) 
Technical data 
Honeywell
Honeywell
Honeywell
Honeywell
 
 
 
4.3 
Technical data 
 
Input voltage U
in 
380 - 500V, -15%...+10% 3~ 
208…240V, -15%...+10% 3~ 
208…240V, -15%...+10% 1~ 
Input frequency 
45…66 Hz 
Mains  
connection 
 
Connection to mains 
Once per minute or less (normal case) 
Output voltage 
0—U
in
 
Continuous output 
current 
I
L
: Ambient peak temperature max. +45°C (with 24h 
average ambient +40°C),* 
     overload 1.1 x IL (1min/10min) 
I
H
: Ambient temperature max. +50ºC, 
     overload 1.5 x IH (1min/10min) 
Starting torque 
150% (Low overload); 200% (High overload) 
Starting current 
 
2 x IH 2 seconds every 20 seconds, if output frequency 
<30Hz  
and temperature of heatsink <+60ºC 
Output frequency 
0…320 Hz 
Motor 
connection 
Frequency resolution 
0,01 Hz 
Control method 
 
 
Frequency Control U/f 
Open Loop Sensorless Vector Control 
Switching frequency 
(See parameter 2.6.8) 
1...16 kHz; Factory default 6 kHz 
Frequency reference 
Analogue input 
Keypad reference 
 
Resolution 0.1% (10bit), accuracy ±1% 
Resolution 0.01 Hz 
Field weakening point 
30…320 Hz 
Acceleration time 
0.1…3000 sec 
Deceleration time 
0.1…3000 sec 
Control 
characteristics 
Braking torque 
DC-brake: 30%*TN (without brake option) 
Ambient operating  
temperature 
–10°C (no frost)…+45°C: I
L
   
(ambient temperature derating 1,5%/Cº) 
 
–10°C (no frost)…+50°C: I
H
 
Storage temperature 
–40°C…+70°C 
Relative humidity 
0…95% RH, non-condensing, non-corrosive,  
no dripping water 
Air quality: 
- chemical vapours 
- mechanical particles 
 
IEC 721-3-3, unit in operation, class 3C2 
IEC 721-3-3, unit in operation, class 3S2 
Altitude 
100% load capacity (no derating) up to 1000m 
1-% derating for each 100m above 1000m; max. 3000m 
Vibration: 
EN50178/EN60068-2-6 
5...150 Hz 
Displacement amplitude 1(peak) mm at 5...15.8 Hz 
Max acceleration amplitude 1 G at 15.8...150 Hz 
Shock 
EN50178, IEC 68-2-27 
UPS Drop Test (for applicable UPS weights) 
Storage and shipping: max 15 G, 11 ms (in package) 
Ambient 
conditions 
Enclosure class 
IP20; MF2 and MF3. IP21/IP54; MF4 – MF6 
Technical data (continues on next page) 
* In NXL Compact the maximum ambient operation temperature is +40°C. (+45°C only applies to NXL HVAC)