AC Power and Backup Battery
 
AC Power and Rechargeable Backup Battery
 
The LYNXR Series is equipped with an integral, replaceable, rechargeable battery pack
 
composed of six (6) 
rechargeable 1.2-volt nickel-metal hydride batteries. Select the appropriate battery pack, based on the 
installation’s requirement, and install the battery pack. 
 
 
Model/Part Number 
 
Battery StandbyTime
 
Low Battery Notification 
LYNXRCHKIT-SC 
4-hours (minimum) 
Approximately 1-hour before battery depletion 
LYNXRCHKIT-HC 
24-hours (minimum) 
At least 1-hour before battery depletion 
 
Replacing the Rechargeable Battery
 
 
01009-006-V0
LYNXRCHKIT-HC                       OR                       LYNXRCHKIT-SC
M
XXXX
K5108
RETAINER
BATTERY
RECEPTACLE
BATTERY
CONNECTOR
BATTERY
PACK
TAPE
 
 
 
 
Ensure the control panel assembly is snapped closed prior to applying AC power. 
1.  When battery replacement is required, unplug 
the transformer from the wall outlet, and open 
the control panel cover. 
2.  Remove the battery retainer and disconnect the 
battery pack connector from the receptacle on 
the terminal block PC board. 
3.  Remove the battery pack from the back plate. 
4.  If required, replace the tape that secures the 
battery pack. 
5. Install a replacement battery pack (P/N 
LYNXRCHKIT-SC or LYNXRCHKIT-HC) into the 
back plate. 
6.  Install the battery retainer. 
7. 
Connect the battery connector to the 
receptacle on the terminal block PC board. 
8. After the wiring connection has been made, 
snap the front assembly to the back plate. 
9. Plug the transformer into a 24-hour, 110VAC 
unswitched outlet. 
10. Rechargeable batteries may take up to 48-
hours to fully charge. The “LOW BAT” message 
should clear within four hours or by entering 
Test Mode.