Zone Response Type Definitions 
 
General Information 
During programming, you must assign a zone type to each zone, which defines the way in which the system 
responds to faults in that zone.  Zone types are defined below. 
Type 00 
Zone Not Used 
Zone type 00 is used to program a zone that is not used. 
 
Type 02 
Entry/Exit Burglary #2 
01000-017-V0
 
Zone type 02 is usually assigned to sensors or contacts on which secondary entry and 
exit doors that might be further from the keypad (typically used for a garage, loading 
dock, or basement door).  
Zone Characteristics: 
•  Entry delay #2 is programmable from 0-99 seconds (field 
36). 
•  Exit delay is independently programmable from 0-99 seconds (field 
34). 
•  Secondary entry delay, if armed in the AWAY or STAY mode.  
•  No entry delay when armed in the STAY NO DELAY or AWAY NO DELAY mode. 
•  Exit delay begins regardless of the arming mode selected. 
 
01000-018-V0
 
Type 03 
Perimeter 
Burglary 
Zone type 03 is usually assigned to all sensors or contacts on exterior doors and 
windows. Zone Characteristics: 
• 
Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY NO 
DELAY mode.
 
Type 04 
Interior, Follower 
5890 / 5890PI
01000-019-V1
 
Zone type 04 is usually assigned to a zone covering an entry area (i.e.: foyer, lobby, or 
hallway) that one must pass upon entry (after faulting the entry/exit zone) to reach 
the keypad. It provides an instant alarm if the entry/exit zone is not violated first, 
and protects an area in the event an intruder has hidden on the premises before the 
system is armed, or gains access to the premises through an unprotected area.  
Zone Characteristics: 
•  Delayed alarm (using the programmed entry/exit time) if entry/exit (types 01 or 
02) or interior-with-delay (type 10) zone is faulted first.  
•    Instant alarm in all other situations.  
•    Active when armed in AWAY or AWAY NO DELAY mode.  
•    Bypassed automatically when armed in STAY or STAY NO DELAY mode. 
Type 05 
Trouble by Day/ 
Alarm by Night 
Zone type 05 is usually assigned to a zone that contains foil-protected doors or 
windows or covers a sensitive area (i.e.: stock room, drug supply room, etc.) It can also 
be used on a sensor or contact in an area where immediate notification of an entry is 
desired.  
Zone Characteristics: 
•  Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY NO 
DELAY (night) mode. 
•  Provides a latched trouble sounding from the keypad and, if desired, a central 
station report during the disarmed state (day). 
 
Type 06 
24-hour  
Silent Alarm 
Zone type 06 is usually assigned to a zone containing an Emergency 
button (silent emergency). 
Zone Characteristics: 
•  Sends a report to the central station but provides no keypad display or 
sounding. 
Type 01 
Entry/Exit Burglary #1 
01000-017-V0
 
Zone type 01 is usually assigned to sensors or contacts on primary entry and exit 
doors. 
Zone Characteristics: 
•  Entry delay #1 is programmable from 0-99 seconds (field 
35). 
•  Exit delay is independently programmable from 0-99 seconds (field 
34). 
•  Exit and entry delays when armed in AWAY or STAY mode. 
•  No entry delay when armed in STAY NO DELAY or AWAY NO DELAY mode. 
•  Exit delay regardless of the arming mode selected.