Honeywell ADEMCO LYNXR Series Installationsanleitung

Seite von 72
 
–35– 
83 Enhanced Sequential Mode
 
 
By using this mode, you can add, delete, or change the serial number of a transmitter in a zone, but retain 
all other existing data that has been programmed for that zone. Note that the 
83 Enhanced Sequential 
mode requires that all zone information must first be entered using the 
56 Enhanced Zone Programming 
mode for all zones below zone number 26 (4 button key area).    
Note:  Any zone which already has a serial number learned in will not be accessible in 
83 Enhanced 
Sequential mode! 
 
Certain button-type transmitters have more than one button (e.g., 5804). Note that each button must be 
assigned to a different zone. Similarly, the 5816 Transmitter has contact terminals and a reed switch for use 
with a magnet. If using both, each must also be assigned to a different zone.  
This means that the procedures that follow must be repeated for each button-type zone below zone number 
26 or contact on the transmitter. Four zone button-type devices are held in zones 26 and above. They will be 
started on boundaries of zones 26, 30, 34, and 38. These four zone button-type devices will have the option to 
have all information entered in this field. One entry will set the loop number, report code, zone type, and 
input device type for all 4 buttons, and a second entry will enter one serial number into four zones.  
 
Note: Use this mode only after all other zone information has been programmed, including transmitter loop 
numbers except for button-type zones over zone number 26. The panel will stop at zones 26, 30, 34 
and 38 and zone data can be entered as a default here. 
 
Enter Serial Number Sequential mode by pressing 
83. The prompts for 
83 are as follows: 
 
A  01 
Zone Number ------------------------------------ for entering the zone number to be programmed 
 
1A 
Enroll Mode -------------------------------------- Selects method of serial number or viewing 
 
1b 
Enroll Serial Number ------------------------- for entering transmitter serial numbers 
 
Delete Serial Number------------------------- for deleting existing serial numbers 
 
The following explains these prompts in detail. The left two columns identify the prompts and list the 
available entries. The right-most column provides a further explanation of the entries. 
 
Notes: (1)  Entry of a number other than one specified will give unpredictable results. 
 
(2)    In Enhanced Sequential Mode, 4 button type keys will always be enrolled simultaneously. They will be stopped at the 4 button 
boundaries of 26, 30, 34 and 38, provided the zone is free of a serial number. If the first zone of the key has a serial number 
enrolled, the remaining keys cannot be programmed in sequential mode. In addition, if the zone has not been set up (duplicate 
loop, missing zone type, etc.) only entries 0 (skip to the next zone) and 4 (copy the key template) will be allowed. 
 
(3)  You may find it convenient to adjust the volume setting before entering the Programming Mode. This will allow you to clearly 
hear feedback announcements or system beeps. 
 
 
 A 
0I 
 
 
 
 
 
 
Zone number 
Enter the 2-digit zone number. 
[✻] = continue; system searches for zones not 
yet entered (for zones 2 through 25 a zone 
type must be entered), then advances to 
ENROLL SERIAL NUMBER prompt “1b” 
00 = exit Sequential mode 
 
 
 
 
 
 
 
 
 
 
 
Enter the  2-digit zone number of the first transmitter to have its serial 
number entered. The system will announce the Voice Descriptor for the 
selected zone number, if it is programmed. 
 
Press [
] to continue. Starting with this zone number, the system will 
search for the first transmitter that  has all of the following attributes 
pre-programmed in 
56 ENHANCED ZONE PROGRAMMING: 
a) 
Make sure that the appropriate input type was selected in 
56 (RF, 
UR, or BR programmed) 
b) 
Make sure that the appropriate loop number was selected in 
56. 
c) 
No serial number programmed 
d) Zone 
type 
If the first zone number entered does not have one or more of the above 
attributes, the system will search its database for the first zone that 
does, and will display it at the enroll SERIAL NUMBER prompt (1b). 
Pressing 00 exits mode, upon which the prompt “83” blinks, indicating 
the mode is inactive.  
Note:  Two exceptions to the requirement above exist for keys. Four zone 
button type devices (zone numbers 26, 30, 34, and 38) will be 
stopped only if there are no serial numbers enrolled in all 4 zones 
of the key, regardless of the attributes that have been entered. In 
addition, zone types are not required to be present. In this case, 
1A, Option 4 must be selected prior to “Learn”.