–48– 
System Operation 
Keypad Functions 
The keypad allows the user to arm and disarm the system, and perform other system functions, such as 
bypassing zones. Zone and system conditions (alarm, trouble, bypass) are displayed in the display window. 
When an alarm occurs, keypad sounding and external sounding will occur, and the zone(s) in alarm will be 
displayed on the keypad. Pressing any key will silence the keypad sounder for 10 seconds (only once). 
Disarming the system will silence both keypad and external sounders.  When the system is disarmed, any 
zones that were in an alarm condition during the armed period will be displayed (memory of alarm).  To 
clear this display, simply repeat the disarm sequence (enter the security code and press the OFF key). The 
keypad also features chime annunciation, and 3 panic key pairs for silent, audible, fire or personal 
emergency alarms.  These keys can notify the central station of an alarm condition, if that service is 
connected. A summary of system functions is provided below for more detailed information refer to the 
User’s Manual.  
Security Functions 
(Empty boxes represent the user’s security code)
 
Checking system status: 
 
STATUS  
(high level messages); press 
STATUS  
again for secondary messages 
To arm in STAY mode: 
  
                           
STAY  
 
(or installer code + [3]) 
To restart exit delay: 
 
STAY  
 (applies only if system is armed in Stay mode) 
To arm in AWAY mode:
 
                           
  + 
AWAY  
 
(or installer code + [2])
 
To arm with NO DELAY:
 
                           
  + 
AWAY  
or 
STAY  
 
+  
NO DELAY  
 
To arm if Quick Arm is programmed: 
 
AWAY  
or 
STAY  
 (hold down for at least 2 seconds) 
To disarm the system and silence alarms:
  
                           
  +
 
OFF  
 
To bypass a zone(s): 
 
                           
 + 
BYPASS  
 + 2-digit zone number(s)  
To turn Chime mode on or off:
  
FUNCTION  
 +
 
CHIME  
 
Message Center
 
To record a message: 
FUNCTION  
 + 
RECORD  
 
FUNCTION  
 + 
RECORD  
 
To stop recording before end of 20 seconds: 
 
OFF  
 
To play back a message:
 
FUNCTION  
 + 
PLAY   
To skip a message: 
[✻] 
To delete all messages: 
FUNCTION  
 + 
 
DELETE   
(during message replay)
 
 
Volume Control
 
To adjust message playback/system announcement volume:
  
FUNCTION  
 +  
VOLUME  
+ [3]  or [6] 
To mute system announcements: 
 
FUNCTION  
 +  
VOLUME  
 +
 
 
OFF  
 
To restore/unmute announcement & volume: 
 
FUNCTION  
 + 
VOLUME  
+ [3]  or [6]
 
Other Functions
 
To set the time and date: 
 
                             
+
   FUNCTION  
 +  [63] 
To set the scheduling: 
 
                           
  +  
FUNCTION  
 +  [64] 
To activate or deactivate X-10 devices 1-6: 
  
FUNCTION  
 +
 
 
LIGHTS ON  
or
 
LIGHTS OFF  
 +  device number  
To activate or deactivate X-10 devices 7 & 8:
  
                           
 + 
FUNCTION  
+
 
LIGHTS ON  
or 
LIGHTS OFF  
+ dev. No
.
 
To add a user code:  
 
                           
*
+
 
CODE  
 + user number + user’s code (*master code) 
To delete a user code (except Master Code): 
 
                           
 *+
 
CODE  
 + user number (* master code) 
To turn Test mode on:
  
                           
 
+
 
TEST  
  
To turn Test mode off: 
 
                           
 + 
OFF  
  
To use the defined AUX function: 
Press and hold 
AUX  
key 2 secs (4 beeps) +
 
                           
 
To define AUX function:
                           
FUNCTION  
 + 
AUX  
action separated by + 
AUX  
terminated by + 
AUX  
AUX  
 
To send message to pager:
 
Press and hold  
AUX  
key 2 seconds (4 beeps) 
To program Follow Me Announcement telephone number
                           
 + 
FUNCTION  
 +  [65] 
NOTE
If a 5827 Wireless keypad has been installed, it cannot be used to 
activate message playback/recording, programming the real time clock 
or scheduling remotely. In this case, you must use the master keypad on 
the control panel to perform these functions.