Hitachi US7070447-001 Benutzerhandbuch

Seite von 98
Methods of Managing the Switch
Doc Part Number, Version Number
6-7
Draft Level—Hitachi Confidential
“::= { enterprises hicam(399) nsg(2) 
nsgConventions(200) 1 }”.
  The following is an example of the 
modified section of the NSGTC.MIB.
EXAMPLE:
IMPORTS
    MODULE-IDENTITY, enterprises       FROM SNMPv2-SMI;
-- hicamNsgConventions MODULE-IDENTITY
--     LAST-UPDATED "9611082200Z"
--     ORGANIZATION "Hitachi Computer Products (America), Inc"
--     CONTACT-INFO
--             " Hitachi Computer Products (America), Inc
--               3101 Tasman Drive
--               Santa Clara, CA 95054
--               (401) 986-9770
--               
--               support@spd.hitachi.com"
--     DESCRIPTION
--             "This module defines the top level object identifiers for
--             the HICAM Network System Group (NSG).  These object 
identifiers
--             are imported by other internally developed MIB modules."
--     ::= { enterprises hicam(399) nsg(2) nsgConventions(200) 1 }
-- 
hicam          OBJECT IDENTIFIER ::= { enterprises 399 }
nsg            OBJECT IDENTIFIER ::= { hicam 2 }
MeterWare Issues
For the RMON groups to work properly, do the following:
Hitachi’s vendor id must entered to recognize the switch’s MAC address.
Set the device to EthernetRMON.
Listed below are the steps to compile and browse Hitachi’s private MIBs with 
MeterWare:
1.
Launch the MeterWare program.
Note: 
The information regarding the SNMPC mibs compiling procedure 
can be found on Technical Bulletin # US7110002-001