Hitachi US7070447-001 Benutzerhandbuch

Seite von 98
HiSpeed Switch Troubleshooting Guide
12-6
US7070447-001, Rev 01
Draft Level—Hitachi Confidential
For AppleTalk users, must be running software version 1.3.28 or later.
FDDI Port service can only be bounded to VLAN 1.   RIP must be ‘active’ to 
route traffic from one VLAN to another across FDDI.
The FDDI driver execution requires five to six seconds longer than the ATM 
Uplink driver.  This is considered normal operation.  The initial installation of 
the FDDI Uplink will delay the login prompt for approximately 30 seconds 
while the configuration file is updated.  
Troubleshooting FDDI:
 Problem:
The HiSpeed switch is only forwarding broadcast and multicast 
traffic but not unicast traffic to an Ethernet device directly attached 
to the HiSpeed switch.
 Solution:
Use the following solutions:
 Verify that physical port 34 is active using 
vvp
.

If the bridge mode is set to Forwarding, verify that the MAC address 
of the targeted Ethernet device has been learned in the FDDI 
Forwarding table.  This means that either the Ethernet device has to 
initiate the connection to the switch or reply to an ARP request.
!
Caution: 
It is important not to interrupt the boot up sequence during this 
process by either pressing the front panel Reset switch, or cycling power.
Note: 
If the HiSpeed Switch is reset by one of these methods during either 
of the configuration file updates (or even possibly during the driver 
execution), the FLASH may become corrupted and the switch will 
subsequently not boot.  A FLASH format and Zap of the firmware will be 
required to recover.