Heath Zenith SL-5411 Benutzerhandbuch

Seite von 12
3
595-5766-03
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Motion
Motion
The detector is most sensitive to motion across its field
of view.
Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected).
Move the sensor head up,
down, or sideways to change
the coverage area. Keep the
sensor at least 1" (2.5 cm)
away from the lamps.
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
Secure the sensor head by
tightening the clamp screw. Do
not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . .  Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . .  Up to 150
°
Electrical Load . . . . . .  Up  to  300  Watt  Maximum  In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements .  120 VAC, 60 Hz
Operating Modes . . . .  TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . .  1 , 5, 10 minutes
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate
new features in products previously sold.
NOTE:
Sensor has a 1 
1
/
2
  minute warm up period
before it will detect motion. When first turned
on, wait 1 
1
/
2
 minutes.
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners.  These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
150
°
MIN
MAX
Least Sensitive
 Most Sensitive
Sensor
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
Maximum Range
Maximum
Coverage Angle
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.