Guardian Technologies Guardian Technologies, LLC Vacuum Cleaner GGU350TT Benutzerhandbuch

Seite von 8
plEaSE rEad all inSTrucTionS bEForE uSinG ThiS appliancE
E-4
WARNING! Do not use the Dirt Cup Handle to move the cleaner.
THERMAL RESET BUTToN: 
Operates due to overheating, caused by a full dirt cup, clogged filter or blocked pipes.  
Unplug the cleaner and remove the blocked materials. To operate again, after  
cooling down the cleaner about 30 minutes, press the Thermal Reset Button.
Model .................................................. GGU350TT
Rating .................................................. 120V/60Hz
Amperage ............................................... 12 amps
Weight (Net) .......................................... 20.50 lbs
Dimensions ............................. 15" x 14" x 45.25" 
Cord Length .............................................. 32 feet
Inner Filter .......................................... HEPA Filter
Exhaust Filter .................................. Micron Filter
Headlight ......................................................... Yes
Belt .................................................................... Yes 
 
 
Height
Setting 
Control
P
O W
E R
 
 
 
B R
US
H
 
 
Main Power 
Switch
Brush Power
Switch
Handle
Handle 
Extension 
Button
Handle Inlet
Hose Connector
Canister 
Handle
Body
Dirt Cup
Dirt Cup Handle
Filter
Height Adjustment 
Knob
Canister 
Release Pedal
Headlight
Base
Thermal Reset 
Button
Cord
Plug
Handle Release 
Pedal
Base Hose 
Connector  
(UPRIGHT MODE)
Handle Removal 
Button
Hose Clip
Hose
Hose Cradle
Handle Hose Connector
(TOOLS/CANISTER MODE)
Cord Clip
Cord 
Storage 
Hooks
HoSE CRADLE ASSEMBLy
HoSE CRADLE ASSEMBLy
Set hose cradle on the top of the cleaner. (Fig. 1)
using a phillips screwdriver, secure the 3/4-inch screw.
HoSE ASSEMBLy
insert the body end of the hose into the hose inlet on the top of the cleaner. (Fig. 2)
line up circular tab on hose cuff with inner groove. (Fig. 2)
connect and twist clockwise to secure proper hose connection. (Fig.3)
place hose in hose cradle. (Fig. 4)
insert the base end of the hose into the hose inlet on the base of the cleaner. (Fig. 5)
IMPoRTANT: hose must be connected to inlet on base of vacuum to work in the upriGhT 
mode.
E-5
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
VACUUM ASSEMBLy: UPRIGHT USE
HoSE ASSEMBLy
Hose
Base Hose
Connector
Detail of  
Hose Lock