GSI Outdoors PNEG-338 Benutzerhandbuch

Seite von 32
10. Electrical Load Information
PNEG-338 Portable Dryer Installation Manual
                29
160AB
1 PH 230V
Top Auger
1
6.5
151
61
200
50
Bottom Auger
1
6.5
50
Fan
10 to 12
48
60
(2) Auxiliary
(2) 7.5
62
*
Top Auger
1
3.4
102
39.8
150
60
3 PH 220V
Bottom Auger
1
3.4
60
Fan
10 to 12
33
60
(2) Auxiliary
(2) 7.5
40
*
Top Auger
1
1.7
56
19.9
150
60
3 PH 440V
Bottom Auger
1
1.7
60
Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 7.5
20
*
210AB
1 PH 230V
Top Auger
2
14
169
76
225
60
Bottom Auger
2
14
60
Fan
10 to 12
48
100
(2)   Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
2
6.2
102
40.4
150
50
Bottom Auger
2
6.2
50
Fan
10
28
60
(2) Auxiliary
(2) 7.5
40
*
3 PH 440V
Top Auger
2
3.1
56
20.2
150
60
Bottom Auger
2
3.1
60
Fan
10
14
60
(2) Auxiliary
(2) 7.5
20
*
300AB
1 PH 230V
Top Auger
3
17.7
212
113.4
300
60
Bottom Auger
3
17.7
60
Fan
10 to 17
78
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
3
8.6
121
56.2
175
60
Bottom Auger
3
8.6
60
Fan
15
39
60
(2) Auxiliary
(2) 7.5
40
*
3 PH 440V
Top Auger
3
4.3
65
28.1
150
60
Bottom Auger
3
4.3
60
Fan
15
19.5
60
(2) Auxiliary
(2) 7.5
20
*
375AB
1 PH 230V
Top Auger
3
17.7
212
113.4
300
60
Bottom Auger
3
17.7
60
Fan
10 to 17
78
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
3
8.6
121
56.2
175
60
Bottom Auger
3
8.6
60
Fan
15
39
60
(2) Auxiliary
(2) 7.5
40
*
3 PH 440V
Top Auger
3
4.3
65
28.1
150
60
Bottom Auger
3
4.3
60
Fan
15
19.5
60
(2) Auxiliary
(2) 7.5
20
*
*Auxiliaries run through load and unload breakers.
Dryer 
Model #
Voltage
Motor
HP
Fuel Load 
Amps
Maximum Amps 
with Auxiliaries
Minimum 
Amps
Recommended 
Service in Amps
Branch Breaker 
in Amps