DIAGNOSTIC STATUS CODES 
TRANSISTOR PUMP CONTROL 
 
 
Page  46 
January 2000
 
 
Section 4.7 Pump Control Codes
 
PUMP   
STATUS CODE
 
DESCRIPTION OF STATUS 
CAUSE OF STATUS INDICATION 
-117 
“Card Type” selection is invalid. 
This status code will be displayed when the card type 
selection value is set to an invalid number. 
MEMORY RECALL  
NO
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump 
Controller 
SYMPTOM 
Control will not operate. 
 
POSSIBLE CAUSE 
Invalid card type selection. 
=Review function 17 in the Handset 
Instruction sheets. Adjust and set 
card type value as instructed by OEM 
service manual. 
 
Verify that the correct logic card 
catalog number is installed in the 
controller.
 
NO
GRAPHIC
FOR THIS
STATUS CODE
 
PUMP   
STATUS CODE
 
DESCRIPTION OF STATUS
 
CAUSE OF STATUS INDICATION
 
-127 
Control logic card power supply is less 
than 10 VDC. 
This status code is displayed when the logic card 
power supply is less than 10 volts. 
MEMORY RECALL  
YES
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump 
Controller 
 
 
 
SYMPTOM 
Control will not operate. 
  
POSSIBLE CAUSE 
 
Discharged Battery 
=Check battery to insure proper state of 
charge. 
 
Loose connection at P1. 
=Insure that the wire connection at P1 is 
tight. 
 
Defective logic card 
=Replace control. 
 
 
FU3
KEY SWITCH
P1 P2
FU2
POWER CONNECTIONS
POS
A1
NEG
A2
FI
E
L
D
A
R
MA
TURE
+
-
FU1
LINE