Telephone: 800-321-6699 • Fax: 800-996-3821
ETA-ECS6RM SPECIFICATIONS
General
 
 Type    
 Power Sequencer Controller
 
 Sequencer  Sections   
  
 
 Relay  Sections   
  6
 
 Sequence  Timing   
  Unit Settings of 1, 3 or 6 Seconds
 
 Unit  Link   
  3
 
 Power  Supply   
  External Wide Rage 100V–240VAC, UL Approval
 
 Power  Consumption   
  .8W
 
 RoHS  Compliant   
  Yes
 
Dimensions  
  H 1.75" x W 19" x D 10"
 Weight 
 
  7 lbs - 3.1kg
Front Panel
 
 Lights   
  XLR Socket to Provide 12VDC for Optional 16" Atlas Power Gooseneck 
Lamp, AP-GNL18. (Qty 1 Included)
 
 LED Light Switch   
 Two Position On/Off
 
 Activation  Switch   
  Momentary
 
 AC Mains Voltmeter  
  Three Digits Digital
 
 AC Mains Current Meter  
  Three Digits Digital
 
 Indicators   
  System On, External Trigger Mode, Slave Mode 
 
 Channel  Selection   
  Momentary Switches
 
 Channel Selected Indicator  
  Single LED Per Channel, Total Six LEDs
 
 Activation  Indicators   
  Six Bi-Color LEDs, One For Each Channel
Rear Panel
 
 Sequenced Activation / Status Signal Port   
  Six Channels Interconnect port. Trigger Out and Status Signal Return, Euro / 
Phoenix Type Connector
 
 Remote Activation Trigger  
  5-24VDC Continuous 10 mA, Switch Contacts, Euro /  
Phoenix type   Connector
 
 Sequenced Relay Contacts 
  Six Channels, Single Relay Contact SPST Each Channel. Euro /  
Phoenix Type Connector
 
 Sequence Time Selection  
  Setting 1,3,6 Seconds, Dip Switch Select
 
 System Master/Slave Assignment  
  Master 
Slave Unit 1 
Slave Unit 2 
Dip Switch Select
 
 System Control Loop In/Out   
 One IN Control Port, One Loop OUT Control Port, for Slave or Master, Three 
Units Can Be Linked. Connector RJ45 (Not an Ethernet Connection)
 
 EVS  Bypass   
  Extreme Voltage Shut Off Enable / Disable, Dip Switch Assign
 
 LED Light Socket 
  XLR Socket to Provide 12VDC for Optional 16" Gooseneck Lamp, AP-GNL18
 
 LED Light Switch  
  Two Position On/Off
 
 DC Input Jack  
  External Power Supply, Wide Range 100V–240VAC, 20V DCV, UL Listed
ETA-ECS6RM
Electrical Control Sequencer