MLC 104 IP Plus • Hardware Setup
Hardware Setup, cont’d
2-6
MLC 104 IP Plus • Hardware Setup
 
2-7
Both digital input and output modes of the digital I/O ports 
have the ability to turn on an internal pull-up resistor to  
+ 5 VDC (equivalent to SW2 on the previous illustration).
N
  Refer to the 
MLC 104 IP Plus User's Manual for further 
details on configuring this port.
d
  MLS RS-232 connector — This port can control an optional 
Extron switcher or other RS-232 controllable device.
If you connect an optional switcher (such as an Extron  
MLS Series switcher) to the MLC, you must connect a ground 
wire between the switcher and the MLC, as shown in the 
following diagram.
MLC/IR
A B C
MediaLink 
Switcher's
Rear Panel
MLC/IR Port
NOTE
 
You must connect a 
ground wire 
between the MLC 
and MLS.
RS-232  
MLS    
A B
Rx
Tx
GR
OUND
Ground (   )
Transmit (Tx)
B
Receive (Rx)
A
Transmit (Tx)
Receive (Rx)
B
A
MLC 104 IP Plus
Right Side Panel
e
  PWR (power) connector — To provide power to the MLC, 
connect a cable between this port and a 12 VDC, 1 amp 
(maximum) power supply, as shown below.  For power wiring 
instructions, see the diagram on the following page.
Connecting an external power supply 
to an MLC 104 IP Plus
MLC 104 IP Plus
Right Side Panel
12V
PWR
GR
OUN
D
+12V IN
Ground (   )
+12 VDC input
Ground all devices.
An External
Power Supply
(12 VDC, 1 A max.)
N
  Power the controller via an external power supply, not 
from an Extron switcher.  The controller requires a 
separate 12 VDC power supply.
N
  Check the power supply’s polarity before connecting it to 
the MLC.  See the diagram below.
Power Supply
Output Cord
Ridges
Smooth
A
A
0.2” (5 mm) MAX.
MLC's
Power
Port
12V 
PWR 
GR
OUND 
+12V IN
 
SECTION  A–A
Power wiring
f
LAN connector and LEDs 
— An Ethernet connection can be 
used on an ongoing basis to control the MLC 104 IP Plus (and 
the devices connected to it) in an Ethernet network.
Use a straight-through cable for connection to a switch, 
hub, or router.
Use a crossover cable for connection directly to a PC.  
Configure the settings for this port via either SIS commands, an 
embedded Web page, or Global Configurator. 
LAN port defaults
 are as follows:
•      IP address: 192.168.254.254 
      gateway IP address: 0.0.0.0
•      subnet mask: 255.255.0.0 
•      DHCP: off