1. Ethernet
[EWRITE]
Words from the F2 memory are written into the F0 memory in the V7 series of the 
network table number specified for F1.  F3 designates the number of words to be 
written.
Usable Devices
EWRITE: Write to memory
EWRITE F0 F1 = F2 C: F3
Example: Macro command at the V7 (A)
The macro command for V7 (A) to write data in V7 (A) to PLC (B) is shown 
below.
[Contents]
Two words starting from $u100 in V7 (A) are written into D100 in 
PLC (B).
Internal 
Memory
PLC 
Memory
Constant
Memory 
Card
Indirect 
Designation
Double-
word
IP Address
F0
F1
F2
F3
[Description] EWRITE D100
B = $u100 C: 
2
Top memory address 
of the target
Address of the target 
(Network table number)
Top memory address of 
the source
The number of words 
to be transferred
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・
・・・