Crestron electronic C2N-DAP8RC Benutzerhandbuch

Seite von 80
Crestron C2N-DAP8RC  
Digital Audio Processor with Room Control 
Operations Guide – DOC. 8187A 
Digital Audio Processor with Room Control: C2N-DAP8RC 
 13      
Method A (Cresnet address-settable ID) 
1. 
Ensure that the C2N-DAP8RC is the only device connected to the 
control system.  
2. 
Open the Crestron Viewport.  
3. From 
the 
Viewport 
Functions menu, select Set Network ID. The 
Viewport will check the baud rate and then display the "Set Network 
ID" window. 
4. 
In the "Set Network ID" window, select the C2N-DAP8RC from the 
Current Network Devices text window. 
5. 
Select the new Net ID for the C2N-DAP8RC from the Choose the new 
network ID for the selected device (Hex):
 text box.  
6. Click 
Set ID to initiate the change. This will display the message "ID 
command has been sent.”  
7. 
In the "Command Complete" window, click OK
8. In 
the 
Current Network Devices window, verify the new Net ID code. 
(The Net ID can also be verified from the Diagnostics menu. Select the 
Report Network Devices command.) 
9. 
In the "Set Network ID" window, click Close.  
NOTE:  The new Net ID code may also be verified by selecting Diagnostic | Report 
Network Devices
 in the Viewport (alternately, select F4).  
10. 
Repeat this procedure for each C2N-DAP8RC to be added to the 
system. 
Method B (Touch Settable IDs) 
Before using this method, you should have a list of all current network devices and 
their Net IDs, to avoid assigning duplicate IDs.  
Set Net ID by TSID 
These procedures are for TSID-enabled network devices during the initial 
configuration of a Cresnet system or when such devices are being added/replaced. 
1. 
Ensure that all C2N-DAP8RCs are connected to the control system.  
2. 
Open the Crestron Viewport version 3.35 or later.  
3. 
From the Viewport menu, select Functions | Assign Cresnet ID by 
Serial Number
. The “Set Net ID by TSID” window appears. The 
window is first displayed with the data fields empty.