Crestron electronic STX-1550C Benutzerhandbuch

Seite von 36
2-Way RF Compact Color Touchpanel 
Crestron STX-1550C
 
RF CHANNEL 
Each STX-1550C touchpanel communicating to the STRFGWX transceiver must 
have a RF CHANNEL that matches the RF CHANNEL of the STRFGWX. There 
are 16 possible RF CHANNELS ranging from 0 to F (hexadecimal number). The RF 
CHANNEL of the touchpanel must match the RF CHANNEL assigned to the 
STRFGWX. 
NOTE:  A single RF CHANNEL may be used by more than one STRFGWX when 
multiple transceivers are used to expand the roaming capabilities of a touchpanel. 
Refer to the latest revision of STRFGWX Operations Guide (Doc. 5811) for further 
information. The latest version can be obtained from the Downloads page 
(MANUAL Library) of Crestron’s website (
. New users are 
required to register in order to obtain access to the FTP site. 
RF ID 
Every STX-1550C touchpanel communicating with a Cresnet control system via a 
STRFGWX requires a unique RF ID to secure RF communications. There are 15 
useable codes for multiple touchpanel(s) ranging from 01 to 0F (hexadecimal 
number). The RF ID of the unit must match the RF ID specified in the SIMPL 
Windows program.  
NOTE:  Do not set the RF ID to “0”; it is not supported in SIMPL Windows. 
Configuring the Touchpanel 
To configure the touchpanel, it is necessary to access a series of setup screens prior 
to viewing run-time screens that are loaded into the touchpanel for normal operation. 
The Main Menu for configuring the touchpanel appears when a finger is held to the 
touchscreen as power is applied. Remove your finger when the message “SETUP 
MODE” appears on the touchscreen. Holding a finger to the touchscreen for five 
seconds after the “SETUP MODE” message is displayed sets the brightness to high.  
Main Menu 
 
Upon entering SETUP MODE, the Main Menu, shown to the left, displays four 
buttons: TOUCH SCREEN CALIBRATIONDIAGNOSTICS, SETUP, and 
SAVE SETUP AND RUN PROGRAM.  
The Save Setup and Run Program button, located at the upper right corner of the 
Main Menu, saves all of the setup information to EEPROM and displays the main 
page that has been programmed into the system. The remaining buttons on the Main 
Menu open other menus, which are discussed in subsequent paragraphs. 
 
Calibration Menu 
 
Touchscreen Calibration Menu 
Calibration of the touchscreen is required if the active touch area of a button does 
not coincide with the button’s image. Select the TOUCH SCREEN 
CALIBRATION 
button on the Main Menu to display the Calibration Menu, shown 
to the left. The Calibration Menu offers the choice to initiate calibration with the 
Perform Calibration button or return to the previous screen with the Return to 
Main Menu 
button. Choose an option by touching the correct button.  
6  
  2-Way RF Compact Color Touchpanel: STX-1550C Operations 
Guide - DOC. 5812A