Furuno SC-60 Benutzerhandbuch

Seite von 106
4. MAINTENANCE, TROUBLESHOOTING 
 
 
 4-3
5. Press ◄ to choose YES and press the [ENT] key. The test proceeds in the 
sequence shown below. 
HDG OUT1 connector
HDG OUT4 connector
NAV OUT1connector
NAV OUT2 connector
BEACON EXT connector
DISPLAY connector
HDG - -
HDG4 - -
NAV1 - -
NAV2 - -
B-EXT - -
DSP
OK
       CNT=     (STOP: PWR OFF)
SOFTWARE VERSION
DISPLAY
205-1312-0**
PROCESS
205-1131-0**
GPS1
205-1313-0**
GPS2
205-1313-0**
GPS3
205-1313-0**
DGPS
085-0182-0**
       CNT=***    (
STOP: PWR OFF)
After 3 sec.
After 3 sec.
<LCD CHECK>
ALL ON 2 SEC.
ALL OFF 3 SEC.
All LCD segments go on 2 sec.,
All LCD segments go off 3 sec.
ROM, RAM, KEY check appears after
3 sec.
ROM RAM
BAT
GPS1
OK
OK
PUSH KEY
GPS2
OK
OK
GPS3
OK
OK
CAL
OK
OK
OK
DISP
OK
OK
OK
DGPS
OK
OK
         CNT=       (STOP: PWR OFF)
Number of times test executed
GPS receiver
Processor unit
Display unit
Factory use
Internal beacon receiver
KEY TEST
Press each key one by
one. Pressed key’s name
appears here if key
is functioning properly.
To stop the test turn 
off the power.
I/O TEST
ROM, RAM, KEY TEST
DISPLAY TEST
PROGRAM VERSION
DISPLAY
** = Program version no.
*** = No. of times test conducted
         consecutively.
OK shown for normal;
NG (No Good) shown for error
 
Diagnostic test sequence 
6.  Turn off the processor unit to quit the diagnostic test1.