INSTALLATION 
 
INSTALLATION PREPARATION 
The first step is to ensure the Harvester has been installed properly.  Improper installation will create 
long-term operational and maintenance problems that will plague the homeowner until corrected.  If an 
exhaust vent system is run over ten feet, Country Flame recommends a four-inch versus three-inch vent 
pipe be used in the exhaust vent system.  The basic installation system should include a clean out T, a 
wall thimble, an exhaust system cap (such as a jet cap) and various lengths of double walled vent pipe. 
 
STOVE CLEARANCES 
The Harvester minimum clearances must be maintained during installation.  Failure to maintain proper 
clearances can create a hazardous environment that will lead to a house fire or endanger the occupants.  
A stove that is installed correctly and maintained properly will minimize operating costs.  Country 
Flame recommends the use of a Hearth Industry Professional that is certified to install pellet-burning 
products.  Check with the local dealer or contact Country Flame if there is any question about the 
installation, the installer, or the product being installed.  Maintain the clearances shown in FIGURE 10.  
Follow the chimney manufacturer’s installation instructions when installing the chimney system.  
Inevitably there will be differences between the chimney manufacturer and Country Flame’s stove 
clearances.  Always utilize the largest clearance listed.  Contact Country Flame or one of its local 
authorized dealers to resolve any questions. 
 
MINIMUM CLEARANCES 
TABLE 2 provides clearances for a Harvester installation using type L or type PL pellet stove pipe. 
 
CLEARANCE TO 
COMBUSTIBLES 
TYPE L OR 
TYPE PL VENT 
PIPE 
A.  SIDEWALL TO UNIT 
2” 
B.  BACK WALL TO UNIT 
1” 
C.  CORNER TO UNIT 
1” 
D.  SIDEWALL TO CONNECTOR 
3” 
E.  BACK WALL TO CONNECTOR 
3” 
F.  CORNER TO CONNECTOR 
3” 
TABLE 2:  REQUIRED CLEARANCES 
COMBUSTIBLES
           FRONT
FLOOR PROTECTOR
COMBUSTIBLES
CO
MB
US
T
IB
L
E
S
CO
M
B
US
T
IB
L
E
S
 
FIGURE 10:  FREESTANDING CLEARANCE REQUIREMENTS