Connect Tech CTIM-00015 Benutzerhandbuch

Seite von 25
BlueStorm Installation Guide, Connect Tech Inc. 
 
Revision 0.08 
23 
 
 
Hardware Installation 
Turn the power off to your computer and open it to expose the expansion slots (consult your 
system’s documentation for more information about this procedure).  
 
Choose an available PCI expansion slot, remove the expansion slot cover and insert the 
BlueStorm adapter, pushing down gently until the board seats fully in the slot.  Secure the 
BlueStorm card to the computer chassis. 
Software/Driver Installation 
BlueStorm provides support for QNX 4.X/6.X, Windows 2000/CE/XP/XPe/XP x64/Server 
2003/Server 2003 x64,Vista, VxWorks, Ardence RTX and Linux.  For installation guidelines 
and driver codes, please refer to the appropriate directories on the BlueStorm CD.  For further 
information concerning software installation of BlueStorm products please visit Connect Tech’s 
 
 
If you are interested in a device driver for an operating system not listed please contact the 
.   
 
Specifications 
Operating Environment 
BlueStorm/LP 
 
Storage temperature: 
  -55°C to 125°C 
 
Operating temperature:     0°C to 70°C  
     Humidity: 
                    5 to 95% non-condensing 
 
BlueStorm/SP, BlueStorm/SP Opto and BlueStorm/SP RJ-11 
 
Storage temperature: 
  -55°C to 105°C 
 
Operating temperature:     0°C to 70°C  
 
Humidity: 
                    5 to 95% non-condensing 
PCI Bus Interface 
BlueStorm/LP 
3.3V or 5V PCI bus.  
Please note that the BlueStorm/LP can ship with low and standard profile brackets. 
 
BlueStorm/SP, BlueStorm/SP Opto and BlueStorm/SP RJ-11 
3.3V or 5V PCI bus 
Communications 
Baud Rates 
RS-232:  50 bps – 921.6 Kbps 
RS-422/485:  50 bps – 1.8432 Mbps 
 
Custom baud rates are also available; please contact our 
 for information.