Connect Tech CTIM-00015 Benutzerhandbuch

Seite von 25
BlueStorm Installation Guide, Connect Tech Inc. 
 
8                                                                                                                                                  Revision 0.08 
 
Multi-drop Slave Mode 
In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is 
enabled all the time.  This mode is typically used in multi-drop 4-wire connections.  This mode 
requires software setup in 
Control Panel – System Properties – Hardware - Device Manager – Ports – CTI 
PCI UART
.  Click on 
Advanced
 under 
Port Settings
.  
Line Bias/Termination 
The RS-422/485 transceivers, both transmit and receive are optionally biased to produce a line 
level mark condition through jumper selectable resistors.  These options are typically used in 
multi-drop 4-wire connections.  
 
Jumper Block Diagrams for BlueStorm  
 
 
Figure 1: BlueStorm/LP jumper block locations, 2 port models