Step 7
Inspect O-rings for wear and replace them if needed (order
part no. WP113029 from Watts.) Lubricate O-rings with a water
soluble lubricant such as KY Jelly®, (petroleum based
lubricants such as Vaseline® must not be used.) Be sure to
properly seat the O-ring in the housing before threading the
housings onto the lid assembly.
Note: Keeping the RO module in an upright position while re-
attaching the housings will help ensure the o-ring stays properly seated and reduces
the possiblity of leaks.
Step 8
The sediment filter has a cloth like appearance. It must be
placed in the 1 st housing on the left where the water inlet
connects.
Step 9
The carbon bock filter has a mesh covering and has a
gasket on each end. Replace the filter in the 2nd housing
with the carbon block filter.
Step 10
Visually inspect oring to be sure they are properly seated before threading the housing
onto the lid assembly and hand tighten securely.
Annual Maintenance
Step 1.
Perform Semi-annual Preventive Maintenance Steps on page 8.
Note: For the annual maintenance drain the tank.
Step 2
Replace the final filter by removing the white nuts from both ends of the filter. Remove the
connectors from both ends (keep and reuse). Discard the old final filter and replace with new
filter reusing the connectors.
Note: Flow arrow on final filter must be pointing in the direction of water flow to the
faucet.
Step 3
The tank shut off switch has quick-disconnect connectors. Remove the blue tube from the
tank side of the tank shut-off switch. Depress the gray ring with the tip of your finger and
pull the tube straight out .
Step 4
Use a clean eye dropper to insert ½ teaspoon of 3% hydrogen peroxide or common house
hold bleach into the blue tube. (This will flow into the tank
once water is turned back on to unit.)
Step 5
To reconnect insert tube into the connector and push
firmly.
Step 6
Follow Start Up procedure on page 8.
9