Clarity Bay Cat X SN-4620-1080 Benutzerhandbuch

Seite von 143
6
2.1 Installing the DVI Board or SDI Board
Clarity Visual Systems ships the DVI or SDI board separately from the Bay Cat X to some customers and for field 
upgrades.
The DVI Board is the field-installed video board for 
the Video Model of Bay Cat X. The SDI Board is 
the field-installed video board for the Broadcast 
Model of Bay Cat X.
1. If you powered up the unit to confirm proper working 
order upon receipt, turn off AC power to the Bay Cat X 
and remove the power cord.
2. Place the unit face down on a flat surface on something 
soft and non-scratching. If your unit does not have a 
protective face glass panel, be EXTREMELY careful as 
the LCD material can be scratched.
3. Confirm that your DVI Board package contains four (4) 
mounting screws (SDI Board package contains six[6] 
srcews), a replacement DVI or SDI cover panel, and a 
disposable grounding wrist strap.
4. On the back of the Bay Cat X, remove the blank cover 
panel.
a) Unscrew the two screws holding the blank panel in 
place. Save the screws for the replacement panel you 
will install later.
b) Remove the blank panel by pushing down slightly 
on the inserted end of the panel as you pull it out.
c) Recycle the blank panel with other aluminum scrap 
metal.
5. Attach the grounding wrist strap to bare metal on the 
chassis. Using standard ESD procedures, remove the 
As you remove the panel, 
push down slightly on this 
end of the panel as you pull 
it towards you