Apollo CNX80 Pilot’s Guide
23
5. Turn the Large knob to move to the Type selection. Turn the Small 
knob to choose between Differential, Ground, or Air. Differential 
means the value was referenced to another calibrated source or 
unit. Ground means the unit was calibrated while on the ground. Air 
means the unit was calibrated while in the air. 
6. Turn the Large knob to move to the Location selection. Press the 
Cursor knob in to start editing. Turn the Small knob to change the 
character. Turn the Large knob to the next character and turn the 
Small knob to change the character. When editing is complete, 
press the Cursor knob again to exit editing the Location. 
7. Turn the Large knob to move to the Brg Error selection. Turn the 
Small knob the change the value required to center the needle. Left 
for “-” and right for “+” corrections. 
8. Turn the Large knob to move to the Name selection. This value if for 
recording the name of the person entering the values in the Test 
Log. Press the Cursor knob in to start editing. Turn the Small knob 
to change the character. Turn the Large knob to the next character 
and turn the Small knob to change the character. When editing is 
complete, press the Cursor knob again to exit editing the Name. 
Na
v Rad
io
CNX80 Pilot Guide 560-0984-00C Draft1.book  Page 23  Tuesday, September 2, 2003  10:36 AM