Ampro Corporation XTX 820 Benutzerhandbuch

Seite von 110
Chapter 3 
Hardware
XTX 820
Reference Manual
43
Pin #
Signal
Description
26
LCDD10
LVDS Channel Data Line 10
27, 28
GND
Ground
29
LCDD04
LVDS Channel Data Line 4
30
LCDD07
LVDS Channel Data Line 7
31
LCDD05
LVDS Channel Data Line 5
32
LCDD06
LVDS Channel Data Line 6
33, 34
GND
Ground
35
LCDD01
LVDS Channel Data Line 1
36
LCDD03
LVDS Channel Data Line 3
37
LCDD00
LVDS Channel Data Line 0
38
LCDD02
LVDS Channel Data Line 2
39, 40
VCC
DC Power – +5V +/- 5%
41
FPDDC_DAT
Flat Panel I
2
C Data – I
2
C data interface to flat panel parameter EEPROM.
42
NC
Not connected (LTGIO)
43
FPDDC_CLK
Flat Panel I
2
C Clock – I
2
C clock interface to flat panel parameter EEPROM.
44
BLON*
Backlight On – Control signal for external flat panel backlight power.
45
NC
Not connected (BIASON)
46
DIGON
Digital Power On – This signal controls the digital flat panel power up.
47
COMP
Composite Analog Output
48
Y
TV Luminance for S-Video
49
NC
Not Connected (Composite Sync )
50
C
TV Chrominance for S-Video
51
LPT/FLPY*
Parallel/Floppy Select – This input signal selects the parallel or floppy port
signal.  If this signal is Low at boot time, the floppy drive is selected.  If this
signal is High at boot time, the parallel port is selected.  This state can not be
changed until the next boot cycle.
52
NC
Not Connected (Reserved)
53
VCC
DC Power – +5V +/- 5%
54
GND
Ground
55
Strobe*
Parallel Strobe* – This output signal is used to strobe data into the printer.
I/O pin in ECP/EPP mode.
56
AFD*
DENSEL
Parallel Auto Feed * – This is a output signal from the printer to automatically
feed one line after each line is printed.
Floppy Drive Density Select – This signal indicates if a low (250/300kBps) or
high (500/1kBps) data rate is selected.
57
NC
Not Connected (Reserved)
58
PD7
Parallel Port Data 7 – This signal (0 to 7) provides a parallel port data signal
and is the printer data MSB.
59
IRRX
IR Receive Data (HPSIR or ASKIR)