Alvarion BreezeMAX Wi and BreezeACCESS Wi 214486 Benutzerhandbuch

Seite von 291
 
80
Operation
Chapter 4 - System Configuration
Location – A text string that describes the system location. (Maximum length: 255 
characters)
Contact – A text string that describes the system contact. (Maximum length: 255 
characters)
Community Name (Read Only) – Defines the SNMP community access string that 
has read-only access. Authorized management stations are only able to retrieve 
MIB objects. (Maximum length: 23 characters, case sensitive; Default: public)
Community Name (Read/Write) – Defines the SNMP community access string that 
has read/write access. Authorized management stations are able to both retrieve 
and modify MIB objects. (Maximum length: 23 characters, case sensitive; 
Default: private)
Trap Destination (1 to 4) – Enables recipients (up to four) of SNMP notifications. 
„
Trap Destination IP Address – Specifies the recipient of SNMP notifications. 
Enter the IP address or the host name. (Host Name: 1 to 63 characters, case 
sensitive)
„
Trap Destination Community Name – The community string sent with the 
notification operation. (Maximum length: 23 characters, case sensitive; 
Default: public)
Engine ID – Sets the engine identifier for the SNMPv3 agent that resides on the AP. 
This engine protects against message replay, delay, and redirection. The engine ID 
is also used in combination with user passwords to generate the security keys for 
authenticating and encrypting SNMPv3 packets. A default engine ID is 
automatically generated that is unique to the AP. (Range: 10 to 64 hexadecimal 
characters)
NOTE
If the local engine ID is deleted or changed, all SNMP users will be cleared. All existing users will 
need to be re-configured.