♦  Session Retries: Defines the number of times a TFTP session will be repeated 
before the firmware upgrade operation is designated a failure. The range is 1-5 
retries with a default of 3 retries. 
Multiple Unit Configuration Mode 
This feature enables configuration parameters to be downloaded to multiple units 
simultaneously. When you select this option from the Options menu, all 
configuration windows are displayed as write-only. Irrelevant parameters are 
disabled. The multiple configuration mode does not include the General 
Parameters tab that is not supported by units running firmware version 3.0 or 
lower. 
NOTE: 
The Configuration Utility does not resolve the topology of the cell. Therefore, multiple unit configuration 
operations should be done at the location where the BUs are located. 
Select the units whose parameters should be modified from the list box on the 
left-hand side of the window. Use Shift-click and/or Ctrl-click to select multiple 
units. 
Enter the configuration parameter values and click Apply. The following window is 
displayed. 
 
Figure 
 
3-21: Multiple Configuration Mode  
This window lists the selected units and displays the configuration changes to be 
made during the multiple configuration session. Select the Reset units after 
setting parameters 
check box to reset all selected units. 
NOTE: 
To ensure proper configuration changes and avoid SNMP Error messages, do not try to configure in BU 
units parameters that are applicable only to RB units, and vice versa. 
A log of the multiple configuration session is displayed during and after the operation.