DSCover Satellite Products Home Security System SCW904x Benutzerhandbuch

Seite von 64
Section 3: Template Programming
7
Section 3: Template Programming
Template programming allows the Installer to quickly program the minimum functions required for basic operation. The installer is prompted to 
enter a 4-digit code that selects predefined zone definitions, reporting code formats, Troubles & Restorals, and DLS setup (see Digit 1 - 4 tables 
below). The Installer is then prompted to enter the Central Station Telephone Number & Account Code, DLS Access Code, Entry & Exit Delays 
and Installer Code (see entry 5-9 below).
Selecting [ ][8] [Installer Code] [899] displays the default settings for the first 4 options below.
Digit 1 selects 1 of the following 6 options for Zone definitions for the first 8 zones. A ‘0’ in the digit 1 location
indicates that the default settings for the first 8 zones are in place unless overridden. See Section [001]-[002] on page 16 for defaults.
 
Digit 2 selects 1 of the following 6 options for Reporting Codes
Once this section has been entered, the Installer cannot exit until all sections are completed. 
Enter new data and/or Press # key to accept the displayed data and proceed to the next section.
Changing a single digit, then pressing the # key will advance to the next section but will not save the 
changed data. Enter all 4 digits or scroll to the end of template programming and exit to save data.
Zone Definitions (Options 1- 6)
Option
Zn1
Zn2
Zn3
Zn4
Zn5
Zn6
Zn7
Zn8
1 Delay 1
1
1
3
3
3
4
4
4
4
2  Delay  2
2
1
3
3
5
5
5
5
88
3  Instant
3
1
3
3
5
5
5
5
87
4  Interior
4
1
1
3
3
3
3
3
3
5  Interior  Stay/Away
5
1
3
3
6
5
5
5
5
6  Delayed  Stay/Away
6
1
3
3
6
5
5
5
88
87  Delayed  24Hr.  Fire  (Wireless)
Refer to Section 8 for zone definition details
88 Standard 24 Hr. Fire (Wireless)
Opt#
Phone Line 1
Programming Section Phone Line 2
Programming Section
1
Disabled
[380] Opt 1 OFF
Disabled
2
SIA automatic Reporting Codes enabled [350] 1st Phone # [04]
[380] Opt 1 ON
[381] Opt 3 OFF
SIA Automatic Reporting Codes
Enabled
[350] 2nd Phone # [04]
3
Contact ID Reporting Codes enabled
[350] 1st Phone # [03]
[380] Opt 1 ON
[381] Opt 7 OFF
SIA Automatic Reporting Codes
Enabled
[350] 2nd Phone # [04]
[381] Opt [03] OFF
4
SIA automatic Reporting Codes enabled [350] 1st Phone #[04]
[380] Opt 1 ON
[381] Opt 3 OFF
Residential Dial
Enabled
[350] 2nd Phone # [06]
5
Contact ID Reporting Codes enabled
[350] 1st Phone # [03]
[380] Opt 1 ON
[381] Opt 7 OFF
Residential Dial
Enabled
[350] 2nd Phone # [06]
6
Contact ID Reporting Codes enabled
[350] 1st Phone # [03]
[380] Opt 1 ON
[381] Opt 7 OFF
Contact ID Reporting Codes 
Enabled
[350] 2nd Phone # [03]