DSCover Satellite Products Home Security System SCW904x Benutzerhandbuch

Seite von 64
7.2 Programming Worksheets
27
[600] 2-way Audio Control Options (Applies to SCW9047 only)
INTERNATIONAL PROGRAMMING
[700] Automatic Clock Adjust   
Default = 60 
   
 
|________|_________|
   Valid Entries 01-99 Seconds
[701] First International Options
[702] Second International Options
[703] Delay Between Dialing Attempts
Default = 003 
   
 
|________|________|________|
   Valid Entries are 000-255 Seconds (Entry + 5 seconds)
Opt
Def.
ON
OFF
1
Tampers Enabled
Disabled
2
Openings & Closings Enabled
Disabled
3
[A] Key Alarm Enabled
Disabled
4
[P] Key Alarm Enabled
Disabled
5
Duress Alarm Enabled (Listen)
Disabled
6
Opening after Alarm Enabled
Disabled
*7
Bell Active during 2-way Audio Verification. 
Bell Silent during 2-way Audio Verification. 
8
Future Use
* This option must be ON for UL Listed Installations
Opt
Def.
ON
OFF
1
EU
50 Hz AC
NA
60 Hz AC
2
Time Base - Internal Crystal
Time Base - AC Line
3
AC/DC Arming Inhibit Enabled
AC/DC Arming Inhibit Disabled
4
All System Tampers Require Installer Reset
All System Tampers Follow Restoral
5
6-digit User Access Codes
4-digit User Access Codes
6
Busy Tone Detection Enabled
Busy Tone Detection Disabled
7-8
Future Use
Opt
Def.
ON
OFF
1
Pulse Dialing Make/Break Ratio is 33/67
Pulse Dialing Make/Break Ratio is 40/60
2
Force Dialing Enabled
Force Dialing Disabled
3
Future Use
4
1600Hz Handshake
Standard Handshake
5
ID Tone Enabled
ID Tone Disabled
6
2100 Hz ID Tone
1300 Hz ID Tone
7-8
Future Use