Section [600] 2-way Audio Control Options (applies to SCW9047 only) 
Section [700] Automatic Clock Adjust
Program the number of seconds for the last minute of the day. This can be used to make minor corrections to the clock if the AC frequency is not 
reliable. Valid entries are [01] to [99]
The following attributes are available for PGM Output Type [09]
[1]
ON: PGM output activates if a Service Required trouble condition is present.
[2]
ON: PGM output activates if an AC trouble condition is present.
[3]
ON: PGM output activates if a Telephone Line trouble condition is present.
[4]
ON: PGM output activates if a Failure to Communicate trouble condition is present.
[5]
ON: PGM output activates if a Zone Fault condition is present.
[6]
ON: PGM output activates if a Zone Tamper condition is present.
[7]
ON: PGM output will activates if a Wireless Low Battery trouble condition is present.
[8]
ON: PGM output will activates if a Loss of Clock trouble condition is present.
The following attributes are available for PGM Output Type [10]
[1]
ON: PGM output activates if a Burglary Alarm occurs.
[2]
ON: PGM output activates if a Fire Alarm occurs.
[3]
ON: PGM output activates if a Panic Alarm occurs.
[4]
ON: PGM output activates if a Medical Alarm occurs.
[5]
ON: PGM output activates if a Supervisory Alarm occurs.
[6]
ON: PGM output activates if a Priority Alarm occurs.
[7]
ON: PGM output will activates if a 24-Hour Duress Alarm occurs.
[8]
ON: the PGM output activates for the time programmed for the PGM Output Timer. 
OFF: the PGM output will latch until a valid user code is entered.
Option
Description
[1]
ON: Tampers Enabled. The Talk/Listen-in session initiates for tamper conditions
OFF: Tampers Disabled. 2-way Audio is disabled for tamper conditions
[2]
ON: Openings and Closings Enabled. The Talk/Listen-in session initiates for Openings & Closings events
OFF: Openings and Closings Disabled. 2-way Audio is disable for Openings & Closings events
[3]
ON: [A] Key Alarm Enabled. The Talk/Listen-in session initiates for [A] Key Alarm
OFF: [A] Key Alarm Disabled. 2-way Audio is disabled for [A] Key Alarm
[4]
ON: [P] Key Alarm Enabled. The Listen-in session initiates for [P] Key Alarm if the [P] Key is programmed to be Silent. If the [P] 
Key is programmed to be audible, the 2-way audio session will be Talk/Listen-in. 
OFF: [P] Key Alarm Disabled. 2-Way Audio is disabled for [P] Key Alarm
[5]
ON: Duress Alarm Enabled (Listen). The Listen-in session initiates for Duress Alarm
OFF: Duress Alarm Disabled. 2-Way Audio is disabled for Duress Alarm
[6]
ON: Opening after Alarm Enabled. The Talk/Listen-in session initiates for Opening After Alarm 
OFF: Opening after Alarm Disabled. 2-Way Audio is disabled for Opening After Alarm
[7]
ON: Bell Active during 2-way Audio Verification. The sounder will remain active during a 2-way Audio session when an audible 
alarm is present OFF: Bell Silent during 2-way Audio Verification. The sounder will be silent when a 2-Way Audio session begins 
when and audible alarm is present, allowing the user to hear the operator. The sounder will resume operation for the timeout duration 
if the panel has not been disarmed at the end of the 2-way session 
This option must be ON for UL Listed Installations.