Desa HD-9140 Benutzerhandbuch

Seite von 42
-5-
595-5660-06
Installation
CAUTION: BEFORE STARTING THE INSTALLATION, TURN THE POWER OFF AT THE
CIRCUIT BREAKER.
Loosen the thumb-
screws  holding the
sensor head and lamp
holders.
Adjust the various
parts so that the fix-
ture looks similar to
this illustration.
Finger tighten the
thumbscrews at this
time.
   Wall Mount
   Eave Mount
Loosen the thumb-
screws  holding the
s e n s o r   h e a d   a n d
lamp holders.
Adjust the various
parts so that the fix-
ture looks similar to
this illustration.
Finger tighten the
thumbscrews  at  this
time.
If you want to use the Manual Override feature
you will need to install the fixture on a circuit
controlled by a switch.
If controlling more than one fixture with this sen-
sor, refer to page 6.
Screw the JourneyMan
®
 replacement motion sen-
sor into a base plate or lighting fixture that will
accommodate the sensor.
If your fixture has a gasket, make sure it is in place
before connecting any wires.
Connect the junction box wires to the sensor and
fixture wires as shown below. Twist together and
secure with wire connectors provided.
Standard Wiring
Junction
Box
All White
wires
Green ground
wire to junction
box ground wire
Black sensor
wire to Black
junction box wire
Red sensor
wire to Black
lamp wires