Implementing PID gains, Ixx30…Ixx35 
In PFM mode, the PID Gains can be determined using the following empirical equations: 
 
[MHz]
CLock 
 
PFM
Ixx08
660000
 
Ixx30
 
 
 
 
 
 
 
 
// Channels 5-8 PID Gains (with default clock settings): 
I530,4,100=11190 
; Motors 5-8 Proportional Gain 
I531,4,100=0 
 
; Motors 5-8 Derivative Gain   
I532,4,100=15038 
; Motors 5-8 Velocity FeedForward Gain 
I533,4,100=0 
 
; Motors 5-8 Integral Gain 
I534,4,100=0 
 
; Motors 5-8 Integral Mode 
I535,4,100=0 
 
; Motors 5-8 Acceleration FeedForward Gain 
 
 
 
Note 