Level Meters Submenu
Level Meter Overview
The 
Level Meters
 monitor the Left and Right output signal levels.  They work
on all PCM signals, and can be used to monitor DSDby setting a DSD to PCM
conversion.
The dCS 974 can be used purely as a programmable meter. Because the meters
work on the output data, the filters can be used to change the bandwidth of the
meters. For example, they can be used to monitor 96kS/s data with a 20kHz
bandwidth, by setting the output rate to 44.1kS/s, or the full bandwidth can be
examined by setting the output rate to 96kS/s.
The 
Display Timeout
 function is disabled while the 
Level Meters
 are being
used.
Turning the Level Meters On
To access the Meters, return to the top level menu, select 
Level Meters
 and
press 
Set
 or 
Status
. With an input signal applied, the display will look similar to
this:
The bar consists of 27 segments, each representing 1dB. The dashed
segments at the right end of each bar are the 
Peak Hold
 indicators.
The indicator on the lower of the two bars shows that overloads
 (full scale
signals) have occurred in the last monitoring period, on that channel (it says
Over
” if you peer closely). The decay of the overload is controlled by 
the Peak
Hold
 function in the 
Level Meters
 menu (below).
Numerical metering to a resolution of 0.1dB can be set up instead, for example
for accurate alignment in comparisons.  See 
Meter Type
 below to do this – the
display will change to:
                                                     
11
 because the dCS 974 reduces the signal level by 0.01dB, this can only occur if gain is applied, or if the unit is in
Format Conversion mode and the input signal goes to full scale.