DCS Computer Hardware dCS 974 Benutzerhandbuch

Seite von 131
dCS 974 User Manual
 Manual for Software Version 1.0x
dCS Ltd 
May 2001
Manual part no: DOC1241121A1
Page 92
Document No: OS-MA-A0124-112.1A1
Contact 
dCS
 on + 44 1799 531 999 
email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0)
web site: www.dcsltd.co.uk
Size, Weight and Operating Conditions
Size and Weight
The  dCS 974 dimensions correspond to a standard 2U 19" rack mount case.
Four heavy duty feet, fitted to the base, extend the overall height to slightly
greater than 2U.
Dimensions
Width 
430 mm see note (i)
Height, without feet
88 mm
(2U)
Height, with feet 
95 mm
Depth
390 mm  see note (ii)
Weight
8.5kg
see note (iii)
note (i)
Removable 19" rack mount ears are supplied,
taking total width to 483 mm (19").
note 
(ii)
Measured from front panel to rear panel
connectors. Additional depth should be allowed to
accommodate cable connectors. The rotary control
knob protrudes 22mm from the front panel.
note 
(iii)
The high quality case is necessarily heavy,
consideration should be paid to appropriate
support shelving when installing the units in a rack.
Operating Conditions
The case of the dCS 974 has no ventilation slots or fan cooling, to give:
•  quiet operation (does not need to be installed in a machine room)
• internal 
temperature 
stability
•  improved electrical safety
•  long term reliability
•  no regular maintenance or cleaning requirements
It dissipates relatively low power, so that usually allowing natural convection
provides enough cooling. Do not install the unit near heat sources such as
radiators, air ducts or direct strong sunlight. Ambient should not exceed 50°C,
should not fall below 0°C, and should be non condensing. If in doubt, the easy
test is – the dCS 974 is happy to work anywhere a human is.