Blodgett B24C-FF Benutzerhandbuch

Seite von 20
S
ECTIONAL 
F
RYER 
F
ILTER 
S
YSTEM
 
S
PECIFICATIONS
 
O
WNER
M
ANUAL 
1184960 P
AGE 
5
 OF 
20 
G
AS 
S
UPPLY
 
The Sectional Fryer Filter System does not use any gas, but it does have a 1-1/4" front gas manifold the couples to 
the adjacent sectional unit(s). 
E
LECTRICITY 
S
UPPLY
 
The Sectional Fryer Filter System requires electric power (50Hz or 60Hz single-phase AC). 120V models draw a 
maximum of 6.5 amps, and have a 7-foot (2134 mm) power cord with a grounded plug. 230V models draw a 
maximum of 2.6 amps, and have a terminal block for connection to a single-phase 230V source. 
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of 
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as 
applicable. 
V
ENTILATION
 
 WARNING 
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products 
can cause headaches, drowsiness, nausea, or could result in death. 
All gas appliances must be installed in such a manner that the flow of combustion and ventilation air is not 
obstructed. Provisions for adequate air supply must be provided. 
 
NOTICE 
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the 
warranty. 
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s 
instructions. 
 
The Sectional Fryer Filter System is electrically powered, and so does not require combustion air. However, the flue 
riser may contain exhaust gasses from adjoining appliances that share an optional continuous flue riser. Follow the 
ventilation requirements for the adjoining section(s).