4.  Discover the MES1A/B on the Network 
‰ 
Open the Device Installer software. It should detect the 
MES1A/B and display XPort in the third level of the Devices 
Tree. 
‰ 
Expand the Devices Tree and click the device IP Address. 
‰ 
Select the Telnet Configuration tab, then click Connect. 
‰ 
When the Modbus/TCP to RTU Bridge,  MAC address and 
Software version information appears, Press Enter to go into 
Setup Mode.
 
5.  Configure the MES1A/B 
‰ 
To change the IP Address, Default Gateway or Netmask, type 1. 
‰ 
To configure Master/Slave and serial Interface settings, type 2. 
‰ 
Do not change any configuration settings in section 3. 
‰ 
To configure Modbus/TCP settings, type 4. 
‰ 
To configure Modbus Master settings, type 5. 
‰ 
To save your settings to the MES1A/B, type S. 
6.  Modbus Device Installation 
‰ 
Connect the Modbus device to the serial interface on the 
MES1A/B using the correct cabling: 
‰ 
MES1A is a DTE: Use a straight through serial cable if the 
Modbus device is a DCE; null modem if device is DTE. 
‰ 
MES1B: Four-wire for RS-422, Two-wire for RS-485, Set 
RS-422/485 switch. 
‰ 
Your Modbus device should now be operational on the network. 
Note: The MES1A/B can be reset (rebooted) by pressing the 
Reset switch for one second. Reset switch is accessed through a 
small hole in the top of the enclosure.