B&B Electronics Switch 232SS21600 Benutzerhandbuch

Seite von 26
232SS21600Manual
11
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
The “M” tells the 232SS2 it is the set timer mode command and the
“1” indicates to set up the timer to ignore switching commands.
When the timer is configured in this mode, the 232SS2 will not
accept any switching commands (“A”, ”B”, ”C”, ”D”, or “EOT”) for the
specified timer value. After the timer has expired, the slave port that
is connected to the master port will be disconnected. This feature is
useful to prevent inadvertent switching during binary/graphic type file
transfers. For example (smart switch mode):  The timer is
configured to ignore switching commands for 5 seconds. The select
Port D command is sent to the 232SS2. Once Port D is connected a
file of unknown data type (so file may or may not contain a switching
command sequence) is to be transferred through the 232SS2. For a
period of 5 seconds after Port D is connected, no switching
commands will be accepted. As long as the file transfer takes less
than 5 seconds, there is no chance the 232SS2 will inadvertently
switch ports.
Specifications
Model:
232SS2
Size:  
6.2 x 8.0 x 2.5hin
Power:   12Vdc to 16Vdc @ 100mA
Table 4 - 232SS2 Commands
Command Characters
Function
1st
2nd
3rd
4th
Comments
Select Port A
ESC
X*
“A”
NU**
Switching
Command
Select Port B
ESC
X*
“B”
NU**
Switching
Command
Select Port C
ESC
X*
“C”
NU**
Switching
Command
Select Port D
ESC
X*
“D”
NU**
Switching
Command
Deselect Port
ESC
X*
EOT
NU**
Switching
Command
Set Timer Value
ESC
X*
“T”
“0”-”9”
Enhanced
Mode
Set Timer Mode
ESC
X*
“M”
“0”,”1”
Enhanced
Mode
*X represents the programmable character set by dipswitch SW2
**NU = Not Used