B&B Electronics Switch 232SS21600 Benutzerhandbuch

Seite von 26
232SS21600 Manual
15
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
If the software was installed in the default directory:
At the DOS prompt Type C: and press the ENTER key.
Type CD\232MSS2 and press the ENTER key.
To begin the SSTSR program (the following will be used as an
example):
Type  SSTSR A03F8 B7 D8 P1 U8 H6 and press the ENTER
key.
Using this method, every time you want to install the SSTSR
with different parameter settings than the default (refer to the Default
Values section), the missing parameter must be specified.
Parameters
The Port Address is the address where the serial
communications port is located.
Some of the typical port addresses are as follows:
The Baud Rate is the speed at which communication takes
place between the SSTSR and the Smart Switch. It must be
specified so that it is equal to SW1 on the Smart Switch.
The Number of Data Bits is the length of each character that
gets sent from the SSTSR to the Smart Switch. This value must be
specified so that it is equal to SW2 on the Smart Switch.
The Parity is a method of error detection that takes place during
the transmission of data between the SSTSR and the Smart Switch.
This value must be specified so that it is equal to SW2 on the Smart
Switch.
The User Defined Character must be set so that it is equal to
SW3 on the Smart Switch.
Port Address = 03F8
Parity = Odd
Baud = 9600
User Defined Char. = 8
Data Bits = 8
Hot Key Sequence = 4
Port
Address
COM 1
03F8h
COM 2
02F8h
COM 3
03E8h
COM 4
02E8h