Example 3 
 
 
DEVICE = C:\DSP-100\DSP100CL.SYS (s0,b300,i5) 
 
In example 3, a single command line argument is provided.  The 
Client Driver will attempt to configure a 232PCC2 inserted into 
socket 0 with a base address of 300H and IRQ 5.  If address 300H 
or IRQ 5 is unavailable, the 232PCC2 will not be configured.  In 
addition, if a 232PCC2 is inserted into any other socket, it will not be 
configured.  If the Client Driver can successfully configure the 
232PCC2, its interrupt status register will be enabled. 
 
Example 4 
 
 
DEVICE = C:\DSP-100\DSP100CL.SYS (i5,e,u,b300) 
 
In example 4, a single command line argument is provided.  
Because the parameter order is not significant, the Client Driver will 
attempt to configure a 232PCC2 inserted into any socket with a base 
address of 300H and IRQ 5.  If address 300H or IRQ 5 is 
unavailable, the 232PCC2 will not be configured.  If the Client Driver 
can successfully configure the 232PCC2, its interrupt status register 
will be disabled (Scratchpad registers enabled). 
 
Example 5 
 
 
DEVICE = C:\ DSP-100\DSP100CL.SYS (b300,i5) (i10) ( ) 
 
In example 5, three command line arguments are provided.  The 
Client Driver first attempts to configure a 232PCC2 inserted into any 
socket with a base address of 300H and IRQ 5.  If address 300H or 
IRQ 5 is unavailable, the Client Driver will proceed to the second 
command line argument and attempt to configure the card with a 
base address assigned by Card and Socket Services and IRQ 10.  If 
IRQ 10 is also unavailable, the Client Driver will proceed to the third 
command line argument and attempt to configure the 232PCC2 with 
a base address and an IRQ assigned by Card and Socket Services.  
If the 232PCC2 is successfully configured, its interrupt status 
register will be enabled.