Notes on Installation 
  Clearance between the module frame and the mount-
ing surface is required to allow cooling air to circu-
late around the back of the module. This also allows 
any condensation or moisture to dissipate. The mod-
ule should never be sealed to the mounting surface 
with sealant that prevents air from circulating under 
the module.
  Leave 4 inches of clearance between the roof and the 
module frame.
  Refer to your local authority for guidelines and re-
quirements for building or structural fire safety.
  For roof application, the modules should be mounted 
over a fire resistant covering rated for the application
Standard Operating Condition
Bosch Solar Energy AG recommends that modules be 
operated under Standard Operating Conditions (SOC). 
An installation location with conditions exceeding SOC 
or with other Special Conditions (see below) should be 
avoided. SOC of Bosch Solar Energy AG modules is as 
follows:
1. Standard Operating Conditions (SOC)
  The modules should be operated only in terrestrial 
applications. No space or other Special Conditions 
(see below).
  The measured ambient temperature of the installa-
tion location should be within –20º C (-4° F) to 40º C 
(104° F).
  The lower and upper temperature limit is defined as 
the monthly average low or high of the installation 
location.
  The relative humidity should be within 45 % to 95 %.
General
All wiring should be done in accordance with applicable 
electrical codes.
  All wiring should be done by a qualified, licensed 
professional. Wiring should be protected to help 
ensure personal safety and to prevent its damage.
  All Bosch Solar Energy AG modules are equipped 
with wires and quick connectors. Modules have been 
designed to be easily interconnected in series.
  Modules can be wired in series to increase voltage. 
Connect wires from positive terminal of one module 
to the negative terminal of the next module. All mod-
ules connected in series should be of the same 
model number and/or type. Make sure the number of 
modules connected in series does not exceed: ((Max-
imum system voltage / Open circuit voltage of the 
module) – 1) at standard condition, AM1.5G, 25 
degrees temperature, 1,000 W/m
2
.
  Connect modules in parallel to increase current. 
Connect wires from the positive terminal of the one 
module to the positive terminal of the next module. 
Do not connect modules in parallel without using a 
connection box. The number of parallel strings de-
pends on the system integrator’s requirements and 
the inverter ratings.
  These modules contain factory installed bypass 
diodes. If these modules are incorrectly connected to 
each other, the bypass diodes, cables, or junction 
box may be damaged.
Notes:
1. Rated electrical characteristics are within 10 % of 
the values measured at Standard Test Conditions
(STC) of: 1000W/m
2
, 25ºC cell temperature and solar 
special irradiance per IEC 60904-3.
Note: Modules in parallel can be done as applicable
60 Cell Module Series
6 Specification
7 Wiring
8 | Grounding |  Maintenance and upkeep | Disposal
Specification I Wiring | 9
Model Number
IN30125 – 225 
Peak / Rated Power (Pmax, Wp)
225
Max Power Voltage (Vmp, V)
29.40
Max Power Current (Imp, A)
7.80
Open Circuit Voltage (Voc, V)
36.90
Short Circuit Current (Isc, A)
8.30
Power Tolerance (%)
± 3
Factory Installed Bypass Diode (Qty)
3
Bypass Diode Rating (A)
15
Max. Series Fuse Rating (Amps)
15
Maximum System Voltage (VDC)
1000
Fire Resistance Rating
Class C
Temp. coefficient of Voc (%/ºC)
-0.32
Temp. coefficient of Isc (%/ºC)
0.032
Temp. coefficient of Pmax (%/ºC)
-0.46
Cable (1Mtr Length-2Nos)
4Sq.mm, 12AWG
Length, mm (Inches)
1660(65.35)
Width, mm (Inches)
990(43.92)
Frame Depth(Thk), mm (Inches)
42 (1.65)
Weight, Kg (Pounds)
20(44.09)
Mounting Hole, mm (inches)
8x12 (0.315x0.472),
Qty- 8
Ground Hole dia., mm (Inches)
Ground back – 5mm 
(0.196) dia., Qty-2
  The installation place should be less than 1,000 m 
(3,280ft) above sea level.
  Installations more than 1,000 m (3,280 ft) are allowed 
only if the wind pressure load for a module is less 
than 2,400N/m
2
 (50PSF).
2. Special Conditions
  The ambient temperature of the installation place 
exceeds SOC.
  The salt damage is heavy at the installation place.
  The hail and snow damage is heavy at the installation 
place.
  The sand and dust damage is heavy at the installation 
place.
  The air pollution, chemically active vapors, acid rain, 
and/or soot, etc. are heavy at the installation place
3. Application Class & Safety Class
The modules are qualified for application class A: Haz-
ardous voltage (IEC 61730:Higher than 50VDC; EN 
61730: Higher than 120  V), hazardous power applica-
tions (Higher than 240 W) where general contact access 
is anticipated (modules qualified for safety through EN 
61730-1 and 61730-2 within this application class are 
considered to meet the requirement for Safety Class II).
Important Notice!
Module 
Version
Positive Pole
Negative Pole
IN xx125
Tyco, Neutral
6-1394461-2
Tyco, Minus
0-1394462-4
Coding for connector plug
1
1