8.1 Mains voltage
Before  connecting  the  unit  to  the  mains,  please  make
sure  that  the  voltage  setting  on  the  unit  matches  the
local voltage! The fuse holder at the AC power connector has
3 triangular markings. Two of these three triangles are aligned
with one another. The unit is set to the voltage shown next to
these  markings  and  can  be  switched  over  by  turning  the  fuse
holder by 180°. IMPORTANT: This does not apply to export
models  designed  exclusively  for  120  V  operation!
+
If  you  set  the  unit  to  a  different  mains  voltage,  be
sure  to  use  a  fuse  of  the  correct  type  and  rating.
Please  refer  to  chapter  9  “SPECIFICATIONS”  for
details.
+
Blown  fuses  must  be  replaced  by  fuses  of  the  same
type  and  rating!  Please  refer  to  chapter  9
“SPECIFICATIONS”  for  details.
The mains connection is made using the enclosed power cord
and a standard IEC receptacle. It meets all of the international
safety  certification  requirements.
+
Please  make  sure  that  all  units  have  a  proper
ground  connection.  For  your  own  safety,  never
remove  or  disable  the  ground  conductor  from  the
unit  or  of  the  AC  power  cord.  The  unit  shall  always
be  connected  to  the  mains  socket  outlet  with  a
protective  earthing  connection.
8.2 Audio connections
The inputs of your V-AMPIRE come as mono 1/4" connectors.
All line out, line in and headphones outputs are configured as 1/
4" stereo connectors. The line outputs work with both balanced
and  unbalanced  connections.
The DI OUT outputs of your V-AMPIRE are on XLR connectors.
Fig.  8.1:  XLR  connectors
Fig. 8.2: 1/4" TS connector
Fig. 8.3: 1/4" TRS connector
Fig.  8.4:  Headphone  connector