which  meets  the  required  safety  standards.  Blown  fuses  must
only  be  replaced  by  fuses  of  the  same  type  and  rating.  The
mains connection is made via a cable with IEC mains connector.
An appropriate mains cable is supplied with the equipment.
POWER switch
Use  the  POWER  switch  to  turn  on  the  mixing  console.  The
POWER switch should always be in the “Off” position when you
are about to connect your unit to the mains.
To disconnect the unit from the mains, pull out the main cord
plug. When installing the product, ensure that the plug is easily
accessible. If mounting in a rack, ensure that the mains can be
easily disconnected by a plug pull or by an all-pole disconnect
switch on or near the rack.
+
Attention:  The  POWER  switch  does  not  fully
disconnect  the  unit  from  the  mains.  Unplug  the
power  cord  completely  when  the  unit  is  not  used
for  prolonged  periods  of  time.
PHANTOM  switch
The  PHANTOM  switch  activates  the  phantom  power
(necessary  to  operate  condenser  microphones)  on  the  XLR
sockets of the mono channels. The red +48 V LED illuminates
when  phantom  power  is  on.  As  a  rule,  dynamic  microphones
can  still  be  used  with  phantom  power,  provided  that  they  are
wired in a balanced configuration. In case of doubt, contact the
microphone  manufacturer!
+
Connect  microphones  before  you  switch  on  the
phantom  power  supply.  Please  do  not  connect
microphones  to  the  mixer  (or  the  stagebox/
wallbox)  while  the  phantom  power  supply  is
switched  on.  In  addition,  the  monitor/PA  loud-
speakers  should  be  muted  before  you  activate  the
phantom  power  supply.  After  switching  on,  wait
approx.  one  minute  to  allow  for  system
stabilization.
+
Caution!  Please  also  note  the  information  given  in
chapter  6.2.1  “Audio  connections”.
SERIAL NUMBER
Please  note  the  important  information  on  the  serial  number
given in chapter 1.3.3.
6. INSTALLATION
6.1 Rack mounting
The packaging of your mixing console contains two 19" rack
mounts for installation on the side panels of the console.
Before you can attach the rack mounts to the mixing console,
you need to remove the screws holding the left and right side
panels. Then, use these screws to fasten the two rack mounts,
each specifically to one side. With the rack mounts installed, you
can mount the mixing console in a commercially available 19"
rack. Be sure to allow for proper air flow around the unit, and do
not place the mixing console close to radiators or power amps,
so as to avoid overheating.
+
Only  use  the  screws  holding  the  mixing  console
side  panels  to  fasten  the  19"  rack  mounts.
6.2 Cable connections
You  will  need  a  large  number  of  cables  for  the  various
connections  of  the  console.  The  illustrations  below  show  the
wiring of these cables. Be sure to use only high-grade cables.
Fig.  6.1:  Foot  switch  connector
6.2.1 Audio connections
Please use commercial RCA cables to wire the 2-track inputs
and outputs.
You can, of course, also connect unbalanced devices to the
balanced  input/outputs.  Use  either  mono  plugs,  or  use  stereo
plugs to link the ring and shaft (or pins 1 & 3 in the case of XLR
connectors).
Fig.  6.2:  XLR  connections
+
Caution!  You  must  never  use  unbalanced  XLR
connectors (PIN 1 and 3 connected) at the MIC input
jacks if you want to use the phantom power supply.
Fig. 6.3: 1/4" mono plug
6. INSTALLATION