Console Port Speed
Allows you to set the switch service port baud rate to match the baud rate of the
console terminal.
console terminal.
Caution:
If you choose a baud rate that does not match your console terminal
baud rate, you will lose communication with the configuration interface when you
press [Enter]. If communication is lost, set your console terminal to match the
new service port setting.
press [Enter]. If communication is lost, set your console terminal to match the
new service port setting.
Default Value
9600 Baud
Range
2400 Baud, 4800 Baud, 9600 Baud, 19200 Baud, 38400 Baud
Console Password
Enables password protection for accessing the CI through a TELNET session, a
console terminal, or both.
console terminal, or both.
If you set this field to Required, you can use the Logout command to restrict
access to the CI. Thereafter, you will need to specify the correct password at the
console-terminal prompt. Refer to the Console Read-Only Password and
Console Read-Write Password field descriptions for more information.
access to the CI. Thereafter, you will need to specify the correct password at the
console-terminal prompt. Refer to the Console Read-Only Password and
Console Read-Write Password field descriptions for more information.
Default Value
Not Required
Range
Not Required, Required for TELNET, Required for Console,
Required for Both
Required for Both
Console Read-Only
Password
Password
When the Console Password field is set to Required (for TELNET, for Console, or
for Both), this field allows read-only password access to the CI. Users can
access the CI using the correct password (see Default Value below), but cannot
change any parameters or use the Reset command or Reset to Default
command.
for Both), this field allows read-only password access to the CI. Users can
access the CI using the correct password (see Default Value below), but cannot
change any parameters or use the Reset command or Reset to Default
command.
Default Value
user
Range
An ASCII string of up to 15 printable characters
Console Read-Write
Password
Password
When the Console Password field is set to Required (for TELNET, for Console, or
for Both), this field allows read-write password access to the CI. Users can log in
to the CI using the correct password (see Default Value below), and can change
any parameters.
for Both), this field allows read-write password access to the CI. Users can log in
to the CI using the correct password (see Default Value below), and can change
any parameters.
Note that you can change the default passwords for read-only access and
read-write access to a private password.
read-write access to a private password.
Caution:
If you change the system-supplied default passwords, be sure to
write the new passwords down and keep them in a safe place. If you forget the
new passwords, you cannot access the console interface. In that case, contact
Bay Networks for help.
new passwords, you cannot access the console interface. In that case, contact
Bay Networks for help.
Default Value
secure
Range
Any ASCII string of up to 15 printable characters