Baumatic BCG520BL Benutzerhandbuch

Seite von 44
o
 
The cooker is designed to slot in between 600 mm deep 
cabinets, which are spaced approximately 500 mm apart.  
 
o
 
It can also be used as a freestanding unit, with a cabinet to one 
side, in a corner setting or with its back to a wall. 
 
o
 
IMPORTANT:  It should not be installed at the end of a run of 
cabinets, if there is a cabinet at immediate right angles to the 
cooker door. 
 
o
 
The wall behind the cooker and 450 mm above and across the 
width of the cooker should be of an incombustible material and 
preferably an easy clean surface, such as ceramic tiles. 
 
o
 
Any overhanging surface or cooker hood should be at least 700 
mm
 above the highest point on the hob top (including the 
burners). 
 
o
 
Baumatic do not recommend that the cooker is positioned below 
wall cupboards, as the heat and steam from the appliance and 
what is being cooked, may damage the cupboard and its 
contents. 
 
o
 
The cooker may be located in a kitchen, or a bedroom, but not in 
a room containing a bath or shower. The cooker must not be 
installed in a bedroom of less than 20m³ in size.
 
 
 
o
 
The cooker is fitted with four feet 
that can be adjusted to match 
the height of your kitchen 
cabinets. 
 
o
 
If the cooker is not level or is 
unstable due to an uneven floor 
surface, use the adjustable feet 
to alter each corner until the 
cooker is level. 
 
Ventilation requirements 
 
o
 
The room containing the appliance should have an air supply in 
accordance with BS 5440: Part 2.  
 
o
 
For room volumes up to 5m³ an air vent of 100cm² is required.  
 
o
 
If the room has a door that opens directly to the outside, or the 
room exceeds 10m³ no air vent is required.  
 
 
25