Baumatic BCG520BL Benutzerhandbuch

Seite von 44
 
37
o
 
With the control panel removed, refit the oven and gas 
thermostat control knobs. Ignite each burner separately and set 
the control knob to the minimum position. 
 
o
 
Using a suitable screwdriver, turn the screw clockwise to 
decrease the flow of gas and make the flame smaller. Turn the 
screw anti-clockwise to increase the flow of gas and make the 
flamer bigger.  
 
o
 
To establish the correct adjustment, the flame should be 
approximately 3 - 4 mm in length. For Butane / Propane gas, the 
adjusting screw must be tightly screwed in. 
  
o
 
Turn the control knob to maximum and then back to minimum 
two or three times to make sure that the flame does not go out 
when the control knob is set to minimum.  
 
o
 
If the flame does go out, repeat the procedure again.  
 
o
 
Remove the control knobs for the oven and grill and refit the 
control panel and hob top taking care to ensure they are fitted 
correctly. 
 
o
 
Replace all the control knobs.  
 
o
 
Your cooker should now be adjusted correctly to work on LPG 
gas.