Baumatic BC391.3TCSS Benutzerhandbuch

Seite von 40
 
31
o
 
Unscrew the injector and replace it with the 
stipulated injector for the new gas supply 
(see table below). 
 
 
 
 
 
 
 
Gas 
consumption 
Power 
 
 
 
 
(kW) 
Burner Types Pressure  
of gas 
(mbar) 
Injector 
Marking 
(1/100 
mm) 
g/h l/h 
Max. 
Min. 
Natural 
20 
72 - 
95 
(G20) 
 
Butane 
30 50 
73 
(G30) 
Auxiliary 
Propane 
37 50 
71 
1.00 0.48 
(G31) 
Natural 
20 97 - 
167 
(G20) 
Butane 
30 65 
127 
(G30) 
Semi-
rapid 
Propane 
37 65 
125 
1.75 0.60 
(G31) 
Natural 
20 115 - 
286 
(G20) 
Butane 
30 85 
254 
(G30) 
Rapid 
Propane 
37 85 
250 
3.00 1.05 
(G31) 
Natural 
20 135 - 
286 
(G20) 
Wok 
3.50 1.80
Butane 
(G30) 
30 95 
218 
Propane 
(G31) 
37 95 
214 
 
 
o
 
Reassemble all the burners carefully; in particular you should 
IMPORTANT: After changing the injectors YOU MUST follow the 
minimum flow adjustment section on the next page.
 
make sure that the flame spreader is correctly placed on the 
burner.