Encore Presentation System  •  User’s Guide  •  Rev 04
7.  Operations
Working with Layer Functions
3. 
Using the Input Menu, adjust the source in the normal manner.
4. 
To restore Preview to its previous setup, double-punch Source Preview.
Please note the following important points regarding Source Preview:
While the Source Preview mode is enabled, you can only perform input 
adjustments and source selections.  All other layer, destination and output 
functions are disabled.
The Source Preview mode cannot be enabled with "stack" destinations.
rëáåÖ=oÉëÉí
The Reset function is context sensitive.  It is used to reset the current effect to a nominal 
default value on Preview.   
„
Use the following steps to reset a specific PIP or Key parameter:
1. 
In the Layer Control Section, activate the layer that you wish to reset.  The layer 
button blinks to indicate that it is active.
2. 
Ensure that the layer is on Preview.  Typically, you cannot reset functions on 
Program.  
3. 
Ensure that Freeze is off.  Frozen PIPs or Keys cannot be reset. 
4. 
If required, access the "menu" whose specific function you want to reset (e.g., 
borders, shadows, special effects, size, etc.).    
5. 
In the Joystick Section, press Reset to reset the current effect.  
Reset
Note
In some situations (such as size and position), a parameter 
on Program can be reset — provided that Modify Layers on 
Program