Boundless Technologies 4000 Benutzerhandbuch

Seite von 61
26        Setup 
AUXiliary/COMMunications Menu (Sess 2 - AUX)
 
 EXEC1
 
GLOBAL    COMM1 
AUX/COMM2  
KEYBOARD1    SCREEN1 
VISUAL1   MODE1   TAB1  FUNCT1 
BELL 
Mode 
 
Block    H-Blk 
FDX/Line  HDX/Echo 
Baud Rate 
19200 
9600 
4800 
2400 
2000 
1800 
 
 
1200 
600 
300 
150 
134.5 
110 
 
Parity  Odd 
Odd 
Even 
Space 
Mark 
Parity Check 
Yes 
No 
Data/Stop Bits 
7/1
 
8/1            7/2            8/2 
Xon/Xoff  None 
DTR 
DC1/DC3  Both 
Aux Echo 
Yes 
No 
Pace 
 
00 
Terminator 
US/CR 
CRLF/ETX 
XPC 
 
Off
 
On 
 
 ENTER:menu 
 
 :line  
 
 
SPACE:select 
S-SETUP:exit  CTL-SETUP:SES#1
 
Mode
 
[Block, H-Blk, FDX/Line, HDX/Echo] 
Four selections are available for defining communication protocol.  
Baud Rate
 
[19200, 9600, 4800, 2400, 2000, 1800]
 
A wide range of baud rates are available to match the data rate for your printer/host. 
Parity
 
[Odd, Even, Space, Mark]
 
Four selections are available to meet the requirements of your printer/host. 
Parity Check  [Yes, No] 
When Yes is selected, an asterisk (*) symbol will be displayed on your screen at any 
character position where an error in parity is detected by the terminal on incoming 
data. 
Data/Stop Bits
 [
7/1
, 8/1, 7/2, 8/2] 
Select 7 or 8 bit character operation with either 1 or 2 stop bits appended at the end of 
a character. 
Xon/Xoff  [None, DTR, DC1/DC3, Both] 
Select DTR, DC1/DC3 or both for data flow control for received character text.  Flow 
control must be used when using smooth scroll.