Bosch Appliances Video Game Controller D9412GV2 Benutzerhandbuch

Seite von 158
D9412GV2/D7412GV2 | Program Entry Guide | 8.0  SIA CP-01 Quick Reference
EN | 150 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
8.0  SIA CP-01 Quick Reference 
Table 45: Programming the Control Panels for SIA CP--01 Compliance 
 
Prompt Name 
Bosch Recommended Settings 
for SIA CP-01 Compliance 
Shipping Default 
References 
Phone # 
(Prefix backup phone number with 
Call Waiting disable command) 
{Blank} 
Page 11
Duress Type 
Option 3 
0 (disabled) 
Page 35
Cancel Report 
Yes 
Yes 
Page 36
A# Exit Dly Time 
45 sec to 255 sec 
60 sec 
Page 38
A# Duress Enable 
Yes 
No 
Page 39
A# Exit Restart 
Yes or No 
Yes 
Page 49
A# Arm No Exit 
Yes or No 
Yes 
Page 49
A# Two Man Rule 
No No 
A# Early Ambush 
No 
No 
Page 48
A# Exit Warning 
Yes Yes 
A# Entry Warning 
Yes 
Yes 
Page 50
A# Burg Time
1
6 min to 90 min 
6 min 
Page 42
A# Alarm Bell 
1 to 128(64), A, B, C 
A (on-board alarm output) 
Page 79
CC# Entry Tone 
Yes or No 
Yes 
Page 54
CC# Exit Tone 
Yes or No 
Yes 
Page 54
CC# Abort Display 
Yes or No 
Yes 
Page 56
CC# Cancel Display 
Yes or No 
Yes 
Page 56
Master Arm Inst 
{Blank} {Blank} 
Perim Instant 
{Blank} 
{Blank} 
Page 61
L## Send Duress 
[Blank] or E 
E
2
Page 75
L## Disarm 
[Blank] or E 
E
2
Page 67
L## Passcode Disarm 
[Blank] or E 
E
2
Page 75
P## Entry Delay 
30 sec to 240 sec 
30 sec 
Page 94
P## Alarm Abort 
Yes or No 
Yes
3
Page 102
Abort Window 
15 sec to 45 sec 
30 sec 
Page 140
Passcode Length 
3 to 6 digits 
Disabled 
Page 141
Swinger Count 
1 to 2 trips 
1 trip 
Page 141
Remote Warning 
Yes Yes 
Cross Point Time 
5 to 255 sec 
20 sec 
Page 143
P## Cross Point 
Yes or No 
No 
Page 100
1  The SIA allowed range is 1 min to 90 min. 
2  L14 is the default duress user index. 
3  The default for P## Alarm Abort is No for P3, P4, P5, and P22.